<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-20 13-51-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
6.1 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
15 kHz 20 kHz 10232 0,9187
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,0 dBr 3,84 dBr 6,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 20 kHz MIN: 15 kHz % above 76 kHz: 0,9187 Acquired: 2025/06/20 13.50.13 Total samples: 10232 Equivalent time: 0:08:31 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 6,0 dBr MIN: 1,0 dBr AVE: 3,84 dBr % above 12,2 dBr: 0,0 Last value: 2,6 dBr (2025/06/20 13.50.12) 13.36 13.38 13.40 13.42 13.44 13.46 13.48 13.50 0 2 4 6 Pm [dBr]